← All tools

Audio & recording

Room Acoustics Calculator

Calculate axial, tangential and oblique modes in a rectangular room. Estimate RT60 by frequency band and export room modes to CSV.

Dimensions and range

Measure between the finished interior surfaces, including the ceiling height.

1–20 m per dimension.

Estimate RT60 by frequency band · optional

Enter absorption coefficients from 0 to 1 for each band. For walls with different materials, use their area-weighted average. Blank results indicate missing inputs or a model without a finite result.

HzWallsFloorCeiling
125
250
500
1000
2000
4000

How to interpret your room acoustics

What each model calculates

In an ideal rectangular room, modal frequencies are calculated as f = (c/2) × √[(p/L)² + (q/W)² + (r/H)²]. L, W and H are the dimensions in metres. The integer indices p, q and r identify axial, tangential and oblique modes when one, two or three indices are nonzero. The approximation c ≈ 331.3 + 0.606 T uses m/s and °C. Different modes can coincide in frequency, so the table retains each one.

RT60 describes the time for reverberant energy to decay by 60 dB. Per band, Sabine uses 0.161 V / Σ(Sᵢαᵢ). Eyring uses 0.161 V / [−S ln(1 − ᾱ)], where ᾱ is the area-weighted average absorption and S is the total surface area. Both models assume a diffuse field and this calculator omits air absorption. A rug or panel can have very different coefficients depending on frequency and mounting.

Worked example: a 5 × 4 × 2.5 m home studio

At 20 °C, the first length, width and height axial modes are about 34.34 Hz, 42.93 Hz and 68.68 Hz. The second length mode coincides with the first height mode. That overlap is worth checking in a measurement, but its level depends on source and listening positions.

If the 500 Hz coefficients are 0.15 for walls, 0.25 for the floor and 0.12 for the ceiling, the volume is 50 m³ and equivalent absorption area is 14.15 m². Sabine gives about 0.57 s and Eyring 0.52 s. These coefficients are illustrative.

Read the guide to measuring and improving home studio acoustics →

How to check the result with a measurement

  1. Start at your usual listening position and save that measurement as a reference.
  2. Compare the response and decay around the predicted modes. Repeat at nearby positions to see how the issue changes with placement.
  3. Change one variable at a time, such as speaker position, seat position or treatment. Measure again under the same conditions. A deep dip that shifts with microphone position is a reason to review placement before boosting that band with EQ.

For tempo-synced effects, use the delay and reverb time calculator. Room RT60 and a plug-in’s pre-delay describe different phenomena.

Technical references: HyperPhysics · Room EQ Wizard · RWTH Aachen