Voice and practice
Vocal trainer: pitch and practice
Hear a comfortable note, sing it and review your take. Then repeat and compare.
Your project settings
Applying does not start sound or microphone. This trainer supports 40–120 BPM.
1. Choose an exercise
Exercises use C2–C6 and must end within C6. Each step lasts one quarter note, except the four-second held note.
The reference sustains each note so you can hear it before singing.
Reference and comparison band
The band helps compare readings; it is not a grade for your voice.
Reference playback and recording are separate. Microphone audio is not sent to the speakers. Use one voice, without accompaniment.
Microphone and level
Input and level
Recording requests microphone access. Check the level or select another input here.
Test your microphone. If the meter does not move when you speak, choose another input.
Microphone closed
Input level (optional)
Microphone level in HertzKit
How input gain works
100% preserves incoming amplitude; 50% halves it (−6 dB). Adjust from 0 to 200% (+6 dB), including while the microphone is active. Meters show approximate peaks from −60 to 0 dBFS, not acoustic volume. This control changes the signal inside HertzKit, not the hardware gain. If the incoming signal is already distorted, lower the system or interface input. Increasing gain also amplifies noise. This setting is not saved when the tab closes.
2. Listen and record
When another take finishes, the oldest is discarded and the previous B becomes A. Download anything you want to keep first.
Microphone closed
—
Gaps indicate no reliable reading. The curve retains slides and oscillations. Explore has no note targets or key detection.
3. Review your takes
Only the last two takes are kept on this page. They are not saved automatically. Download audio and report before leaving.
The project saves practice references; it does not include audio or the curve. JSON preserves readings and measurements, without audio.
Take A
Take A: the reading is in a different register. Listen to the take and compare its first note with the reference.
View per-note measurements
| Target | Center | P90 span | Within band | With readings |
|---|
Practice project and analysis data
Take B
Take B: the reading is in a different register. Listen to the take and compare its first note with the reference.
View per-note measurements
| Target | Center | P90 span | Within band | With readings |
|---|
Practice project and analysis data
How to read measurements
With readings indicates analyzable signal, not correct notes. Center is the median deviation from the target. P90 spread is the difference between the 5th and 95th percentiles; it does not measure technique or vibrato rate. Within band counts valid readings only. Each target excludes 120 ms at its start and end.
Help and keeping your takes
To choose another input or check its level, open Microphone and level and press Check input. Recording requests microphone access when you start. The selected input stays selected while this page is open.
Choose an exercise and a comfortable starting note. Soft tone and Pure tone sustain the reference notes. Listen to the reference, then press Sing and record. The three-second countdown prepares the take; sing when Recording appears. The input stays fixed during recording.
Choose Take A or Take B to listen and download its WAV or TXT report. Play pauses and resumes; Stop returns to the beginning. Overlay compares compatible curves. Reference and recording play separately; microphone audio is not routed to speakers.
Two takes stay in this page. Completing a third moves the previous B to A and discards the oldest. Canceling preserves completed takes. Download anything you want to keep before leaving; projects and JSON contain no audio.
Scope and limitations
This supports listening and practicing monophonic pitch. It does not assess vocal health, breathing, timbre, voice classification or artistic quality; it does not automatically correct the recording.
Frequently asked questions
Does vibrato mean I am out of tune?
Not necessarily. The curve shows pitch movement and the center summarizes valid readings. Your chosen band is a comparison reference, not a universal artistic rule.
Why can a note have no reading?
Noise, breaths, very soft singing, multiple voices or fast attacks can prevent estimation. A weak fundamental can also produce an octave error. The percentage counts analyzable frames, not correct notes.